自动化应用传感检测与仪器仪表空调多合一测试系统的应用汤忠桂(约克广州空调冷冻设备有限公司,广东清远511685)摘要:制造空调时,需要经过多道检漏、测试等工序。以往这些工序是分散的,独立作业,存在较多的浪费。同时,工序过程不能实时监控,结果数据未形成良好的记录。本文研究了各工序特点,结合智能制造方法,整合分析空调多道工序作业内容,提出了抽真空、制冷剂一次充注、电气安全检测、二次制冷剂充注、制冷剂回收、系统复位等多道工序整合方案,并投入了实际应用,实现了多道工序自动化流水运行和系统自动判定。关键词:多合一测试系统,制冷剂,自动化中图分类号:F426(YorkGuangzhouAirConditioningandRefrigerationEquipmentCo.,Ltd.,Qingyuan,Guangdong511685,China)Abstract:Whenmanufacturingairconditioners,multipleprocessessuchasleakdetectionandtestingarerequired.Inthepast,theseprocessesweredispersedandoperatedindependently,resultinginsignificantwaste.Atthesametime,theprocesscannotbemonitoredinreal-time,andtheresultingdatahasnotbeenwellrecorded.Thisarticlestudiesthecharacteristicsofeachprocess,combinesintelligentmanufacturingmethods,andintegratesandanalyzestheworkcontentofmultipleairconditioningprocesses.Itproposesanintegrationplanformultipleprocessessuchasvacuumpumping,primaryrefrigerantcharging,electricalsafetytesting,secondaryrefrigerantcharging,refrigerantrecovery,andsystemreset.Ithasbeenputintopracticalapplicationandhasachievedautomaticflowoperationandsystemautomaticjudgmentofmultipleprocesses.Keywords:multiinonetestsystem,refrigerant,automation文献标识码:AApplicationofAirConditioningMultiinOneTestingSystemTANGZhonggui0引言空调装配线的重要工艺一般包括抽真空、制冷剂充注、电气安全检测、制冷剂回收、系统复位等。这些工序在传统的空调装配线被分为不同的功能区域,需要配置较长的输送线,占用较大的生产面积,同时需要频繁的重复作业。其中,多联机为提高测试效率,制冷剂充注分为两次充注,分别为运行测试前充注一次,运行测试后再充注一次。结合智能制造技术的应用,整合上述多道工序,并应用RFID、以太网通讯、数据库、MES、传感器等多种技术实现多合一测试系统的应用,实现了多个工序自动按设计逻辑运行,实时监测工艺数据,输入测量...