2023年第3期(总第303期)doi:10.3969/j.issn.1009-3230.2023.03.007应用能源技术29600MW空冷机组基于单耗分析法核算供电煤耗郭庆杰,董广彦?(1.国家能源集团国神公司技术支持中心,陕西西安710076;2.山东鲁软数字科技有限公司,山东济南250011)摘要:以某厂600MW空冷机组为例,统计期内入炉煤总煤量为240t,入炉煤发热量平均值为5600kcal,采用正平衡法计算得出#2机组供电煤耗偏高设计值18g/kW·h;基于单耗分析法计算影响#2机组能耗的各指标因素,合计影响供电煤耗偏高设计值26.39g/kW·h。关键词:单耗分析法;正平衡法;供电煤耗;负荷率中图分类号:TM621CoalConsumptionforPowerSupplyof600MWAir-cooledUnitBasedonSingleConsumptionAnalysisMethod(1.TechnicalSupportCenterofNationalEnergyGroupGuoshenCompany,Xi'an710076,China;2.ShandongLuruanDigitalTechnologyCo.Ltd.,Jinan250011,China)Abstract:Taking600MWair-cooledunitofacertainplantasanexample,thetotalcoalconsumptionofthecoal-firedboilerduringthestatisticalperiodwas240t,andtheaveragecalorificvalueofthecoal-firedboilerwas5600kcal.ThepositivebalancemethodwasusedtocalculatethatthecoalconsumptionforpowersupplyofUnit2washigherthanthedesignvalueby18g/kW·h;basedonthesingleconsumptionanalysismethod,thefactorsaffectingtheenergyconsumptionofUnit2werecalculated,andthetotalimpactonthecoalconsumptionforpowersupplywashigherthanthedesignvalueby26.39g/kW·h.Keywords:singleconsumptionanalysismethod;positivebalancemethod;coalconsumptionforpowersupply;loadrate0引言火力发电厂在计算机组供电煤耗时,多采用正平衡法,由于某厂600MW空冷机组在入入炉煤检测中,较多采用人工化验和计算,以及皮带秤计量的误差较大,测量结果精度无法得到保障,所以通过年度盘煤计算得到的机组供电煤耗,与实际供电煤耗的偏差关系无法得到求证;而基于单收稿日期:2023-01-10修订日期:2023-02-23作者简介:郭庆杰(1979一),男,工程师,本科,研究方向为电力节能、可靠性技术及碳排放管理、碳排放盘查等。文献标志码:AGUOQingjiel,DONGGuangyan?文章编号:1009-3230(2023)03-0029-05耗分析法计算得出的供电煤耗,可以辅助正平衡法反应机组实际运行水平。1�供电煤耗计算方法1.1正平衡法定义供电煤耗即为统计期内发电用总煤量(折算标煤后)与统计期内总发电...