第42卷第10期2023年10月石油化工应用PETROCHEMICALINDUSTRYAPPLICATIONVol.42No.10Oct.2023焦化废水总氮检测方法的优化齐志龙,倪境泽,臧宏展,吴乐昆(河北协同水处理技术有限公司,河北石家庄050035)[摘要]目前采用的行业标准是HJ636一2012《水质总氮的测定碱性过硫酸钾消解紫外分光光度法》,仪器使用的是紫外分光光度计+高压蒸汽灭菌锅相结合。本文通过消解器替代高压蒸汽灭菌锅进行实验,提高实验效率的同时降低了安全风险。【关键词]总氮;高压蒸汽灭菌锅;消解器;哈希总氮[中图分类号]X784D0I:10.3969/j.issn.1673-5285.2023.10.026【文献标识码]A[文章编号]1673-5285(2023)10-0122-03OptimizationofthetotalnitrogendetectionmethodincokingwastewaterQIZhilong,NIJingze,ZANGHongzhan,WULekun(HebeiCollaborativeWaterTreatmentTechnologyCo.,Ltd.,ShijiazhuangHebei050035,China)[AbstractJAtpresent,theindustrystandardusedisHJ636—2012"Determinationoftotalnitrogeninwaterquality,ultravioletspectrophotometrymethodofalkalinepotassiumpersul-fatedigestion",andtheinstrumentusesthecombinationofultravioletspectrophotometerandhighpressuresteamsterilizationpot.Inthispaper,thedigesterisusedtoreplacethehighpressuresteamsterilizationpottocarryouttheexperiment,whichimprovestheexperimentefficiencyandreducesthesafetyrisk.[KeywordsJtotalnitrogen;highpressuresteamsterilizationpot;digester;Hashtotalnitrogen总氮,简称为TN,是衡量水质的重要指标之一,表示水体受营养物质污染的程度。脱氮与降碳、除磷可以并称为污水处理的三大核心,所以总氮的检测尤为重要。目前,焦化废水总氮检测主要使用两种方法:行业标准HJ636一2012《水质总氮的测定碱性过硫酸钾消解紫外分光光度法》(以下简称行标)和哈希总氮。亻行标的原理是在120~124℃时,碱性过硫酸钾溶液使样品中含氮化合物的氮转化为硝酸盐,采用紫外分光光度法于波长220nm和275nm处测定吸光度。其检测过程需要用到高压蒸汽灭菌锅,属于压力容器,过程繁琐,危险系数较高,冷却时间较长。而哈希总氮需要使用哈希DR900便携测定仪+哈希DRB200消解器,*收稿日期:2023-07-13作者简介:齐志龙(1992一),男,分析工程师,主要从事焦化废水、污水处理及水质研究工作。E-mail:qizhilong0914@163.com第10期价格昂贵,且后续需长期使用其试剂包成本较高。为此,使...