可再生能源33NO.082023节能ENERGYCONSERVATION光伏离网系统与供水水泵电机匹配研究李民王重洋畅蓬博(陕西省水利电力勘测设计研究院,陕西西安710001)摘要:在不同的自然资源环境条件下,结合供水需求,充分利用太阳能保障光伏供水系统在全年各时段的运行,在提高供水保障率的同时降低总体造价是系统是否成功的关键。结合光伏供水系统的实际应用,考虑全年不同时段太阳能情况,对太阳能发电单元及供水水泵电机进行优化配置,以实现高效节能利用的目的。关键词:光伏水泵;光伏离网系统;供水保障率中图分类号:TM914.4;TH3文献标识码:A文章编号:1004-7948(2023)08-0033-04doi:10.3969/j.issn.1004-7948.2023.08.009Researchonmatchingbetweenphotovoltaicoff-gridsystemandwatersupplypumpmotorLIMinWANGChong-yangCHANGPeng-boAbstract:Underdifferentnaturalresourceenvironmentalconditions,combinedwithwatersupplydemand,makingfulluseofsolarenergytoensuretheoperationofphotovoltaicwatersupplysystematvarioustimesoftheyear,itisthekeytothesuccessofthesystemtoimprovethewatersupplysecurityratewhilereducingtheoverallcost.Combinedwiththeapplicationoftheactualphotovoltaicwatersupplysystem,consideringthesolarenergysituationatdifferenttimesoftheyear,thesolarpowergenerationunitandthewatersupplypumpmotorareoptimallyconfiguredtoachievethepurposeofhigh-efficiencyandenergy-savingutilization.Keywords:photovoltaicwaterpump;photovoltaicoff-gridsystem;watersupplyguaranteerate1研究概况应用实施地位于渭北黄土高原,月供水量1000m3,水泵总扬程为水池最低运行水位、地形高差、服务水头、沿程水头损失及局部水头损失之和,考虑选型误差及管路具体长度,水泵额定扬程拟定190m,平均日供水时长为6h。当地无实测气象数据,太阳能资源采用卫星数据进行分析。初步分析对比NASA、Solargis及Meteonorm数据库辐射数据在当地的适用性,采用Meteonorm数据库数据进行资源分析,代表年数据采用多年平均法,水平面总辐射量为1277kWh/(m2·a)。为了便于研究供水系统、发电系统及水泵功率的匹配,采用太阳能供电,不设置电化学储能系统,月供水水量一致,供需水的水量由上下储蓄水系统调节。光伏电池组件采用固定式安装,光伏阵列方位角为0°。水泵参数参考6SP型光伏水泵。2常规系统配置根据《牧区草地灌溉与排水技术规...