11LNG接收站海水泵振动故障分析与处理吴海洪(国家管网集团海南天然气有限公司,海南儋州578001)摘要:国内某液化天然气(LNG)接收站海水泵振动故障极大影响现场工艺生产,利用计算流体动力学(CFD)模拟、有限元分析和振动频谱分析,结合现场检查和测试,发现“卡门涡街”、电机与泵体共振为振动故障频繁发生的原因,并给出解决方案,为处理海水泵振动故障提供参考。关键词:海水泵;振动;计算流体动力学(CFD);Ansys;频谱中图分类号:TE95文献标志码:ADOI:10.16443/j.cnki.31-1420.2023.03.004AnalysisandTreatmentofLNGReceivingTerminalSeaWaterPumpVibrationFailureWUHaihong(PipechinaHainanGasCo.,Ltd.,Danzhou578001,Hainan,China)Abstract:Vibrationfailurehappenedtoseawaterpumpofadomesticliquefiednaturalgas(LNG)receivingterminal,whichstronglyinfluencethenormalprocessoperation.Bycomputationalfluiddynamics(CFD),finiteelementanalysis,andvibrationspectrumanalysis,combinedwithon-siteinspectionandtesting,itisfoundthat"CarmenVortexStreet"andresonancebetweenthemotorandpumpbodyarethereasonsforfrequentlyoccurrenceofvibrationfaults,andsolutionsareprovided,whichprovidereferencefordealingwithvibrationfailuresofseawaterpumps.Keywords:seawaterpump;vibration;computationalfluiddynamics(CFD);Ansys;frequencyspectrum0引言海水泵是液化天然气(LiquefiedNaturalGas,LNG)接收站关键设备,为天然气汽化外输提供热交换介质。国内某LNG接收站设计有4台长轴海水泵,额定流量6430m3/h、额定扬程38m、转速745r/min、设计压力0.55MPa、设计温度65℃、操作压力0.41MPa、操作温度30℃。海水泵投入测试使用后,发现存在振动高故障,导致海水输送无法正常运行,极大影响工艺生产[1-2]。引起海水泵振动高故障的原因有很多,包括泵轴轴承失效、泵筒强度不足、涌浪及水力波动等,通过计算流体动力学(ComputationalFluidDynamics,CFD)模拟、有限元分析和振动频谱分析,结合现场检查和测试,发现“卡门涡街”、电机与泵体共振是振动故障频发的原因。通过在泵筒底部增加抱箍以及在泵体基座增加支撑的方式解决上述故障,在保障LNG接收站天然气汽化外输正常运行方面具有重要的意义[3]。1海水泵概述项目配置的立式海水泵主要由电机、联轴器、推力轴承、泵筒、泵轴(总长近14m)、泵轴承和作者简介:吴海洪(1987—...