27电力安全技术第24卷(2022年第12期)零出力改造前后低加运行异常分析张黎明,王俊杰,陈科镭,张艳霞(国电投南阳热电有限责任公司,河南南阳473000)AnalysisonAbnormalOperationofLow-pressureHeaterBeforeandAfterZero-outputTransformationZHANGLiming,WANGJunjie,CHENKelei,ZHANGYanxia(SPICNanyangThermalPowerCo.,Ltd.,Nanyang473000)〔摘要〕介绍某电厂低压缸零出力改造前后7号低加无水位、温升异常的分析与处理过程,通过抽汽管路连接分析、管壁温度测量、温度计校验、汽侧放空气门内漏消除等成功解决了相关异常,为类似问题的处理提供了借鉴。〔关键词〕低压加热器;零出力改造;切缸;温升Abstract:AnintroductionismadeontheanalysisandtreatmentprocessofNo.7low-pressureheaterwithoutwaterlevelandabnormaltemperaturerisebeforeandafterzerooutputtransformationoflow-pressurecylinderinapowerplant.Relevantanomaliesaresuccessfullysolvedbasedontheanalysisofsteampipeconnection,measurementoftube-walltemperature,thermometercalibration,andeliminationofinternalleakageofsteam-sideventvalves,etc.,whichoffersreferenceforthetreatmentofsimilarproblems.Keywords:low-pressureheater;zero-outputtransformation;cylindertransfer;temperaturerise中图分类号:TM621.4文献标识码:A文章编号:1008-6226(2022)12-0027-03低加对应七段抽汽(简称七抽)。额定采暖工况抽汽温度265.4℃、压力0.325MPa,六、七段抽汽(简称六、七抽)温度212.9℃,96.5℃,额定出力工况(turbineheatacceptance,THA)下7号低加温升为25.2℃。高压缸后轴封内二漏(简称内二漏,设计值279.1℃)来高温蒸汽至七抽到7号低加,2号机组内二漏通过改造增加一路并联接到六段抽汽(简称六抽)管道,高负荷时切换至六抽到6号低加回收蒸汽热能,2021年完成两台机组低压缸零出力切缸改造,并于采暖季投入运行。两台机组运行期间均存在7号低加经常无水位运行且温升异常的情况,同时还有2号机组7号低加温升高于1号机组7号低加温升等异常。现场检修排查确认,由于4台低加连续排气管道共用一根DN50母管至凝汽器,各低加排气支管与母管连接顺序与按照压力高低逐级自流的顺序相反,所以,存在排挤导致压力最低的7号低加无法正常连续排0引言针对低压加热器(简称低加)运行异常,经改造消除了低加抽空气管道连接顺序倒置的缺陷,但未彻底解决低加运行中无水位、温升异常等问题,...