分享
ASTM_D_1250_-_80_adjunct_volume_10.pdf
下载文档

ID:183249

大小:12.72MB

页数:420页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_1250_ _80_adjunct_volume_10
ASTM D 1250October 1980Editorial AmplificationofVolume X-Background,Development,and Computer DocumentationThe implementation procedures(Volume X)for the evennumbered tables(Tables 6,24,and 54)do not provide a sufficientexplanation of truncating and rounding.The literal applicationof the implementation procedures would result in a code capableof producing differences from the printed tables of 1 in thefourth derived place at a rate of at least one difference inevery 240 tabulated entries.This insufficiency in the roundingand truncating procedures is a direct result of a lack of clarityin Volume X.This lack of clarity is corrected as described in the followingpages.The corrections to the implementation procedures werevalidated by an exhaustive number-by-number test of the results ofthe API master tape against the tabular representation producedin three different computer systems:Double precision IBM,singleprecision CDC,and a module in a TI-59 calculator.These threetypes of equipment exhibited differences of 1 in the fourth placeat a rate of less than.008 percent(7 entries out of 87,000in Table 6B and less than half that rate in Table 6A).This rateis caused by the differences in the number of places carried byeach machine and represents the maximum degree of software-machineindependence presently attainable.The rate of difference,whilenot quantitatively known,will be less than this for five significantfigure applications.Because of the nature of the calculations,itis believed that the same basic rate of difference will be foundin all of the even numbered tables.The changes outlined below are editorial corrections to theprinted Volume x and do not affect the master tape,the publishedtables,the computer listings,or the balloted standard.AD0125CVL.IX-147Step 3:b.VCF=0.92848397X-236Step 6:b.VCF=0.98114263X-237Step6:b.VCF=1.01171376X-238Step 6:b.VcF=0.92850559X-258Step 6:b.VcF=0.98074695X-260Step 6:b.VCF=0.99007803X-260Step 6:b.VCF=1,00704627X-262Step 6:b.VCF=0.98010882X-276Step 3:b.VCF=0.98108801X-277Step 3:b.VCF=1.01171377X-277Step 3:b.VCF=0.92848393X-364Step 5:b.VCF=0.98071557X-365Step 5:b.VCF=1.01119225X-366Step 5:b.VC=0.92808220X-385Step 5:b.VCF=0.98806704X-386Step 5:b.VCF=0.98055297X-387Step 5:b.VCF=1.00641225X-388Step 5:b.VCF=0.97942377X-402Step 3:b.VCF=0.98050208X-403Step 3:b.VCF=1.01109395X-404Step 3:b.VCF=0.92821201APPROVED AS ANREF.NO.:ISODIS9U1.ZANe总8,裙0PETROLEUMMEASUREMENTTABLESVolume Correction FactorsVolume X-Background,Development,andProgram DocumentationASTM D 1250-80ASTM Designation:D 1250API Standard:2540IP Designation:200Prepared Jointly byAMERICAN SOCIETY FOR TESTING AND MATERIALSAMERICAN PETROLEUM INSTITUTETHE INSTITUTE OF PETROLEUM1980Publication Code Number 12-412508-10AMERICAN SOCIETY FOR TESTING AND MATERIALS1916 Race St.,Philadelphia,Pa.19103

此文档下载收益归作者所有

下载文档
收起
展开