高发射率水浴黑体腔优化设计与测试徐骏,费志禾Δ,王惠芬,兰少飞,费涛,李逸(1.上海卫星装备研究所,上海200240;2.上海航天技术研究院,上海201109)摘要:针对卫星红外载荷高精度定标试验需求,研制高发射率水浴黑体腔。基于Gouffe理论设计黑体腔结构参数,对比两种腔体内表面处理方法,选择喷涂高发射率涂层的工艺;采取分体式圆锥嵌合结构解决传统构型锥尖加工困难、涂层堆积的问题;并通过理论计算、光线追迹仿真和实验测量评价黑体腔的有效发射率。结果表明,所研制的黑体腔有效发射率达0.997,满足高精度红外载荷定标试验需求。关键词:黑体腔;有效发射率;结构优化设计;表面处理中图分类号:O432.1文献标志码:A文章编号:1673-1379(2023)01-0018-06DOI:10.12126/see.2022084Optimaldesignandtestingofhigh-emissivitywater-bathblackbodycavityXUJun,FEIZhiheΔ,WANGHuifen,LANShaofei,FEITao,LIYi(1.ShanghaiInstituteofSpacecraftEquipment,Shanghai200240,China;2.ShanghaiAcademyofSpaceflightTechnology,Shanghai201109,China)Abstract:Ahigh-emissivitywater-bathblackbodycavitywasdevelopedinviewofthehigh-precisioncalibrationtestofsatelliteinfraredloads.ThestructuralparametersofblackbodycavityweredesignedbasedonGouffetheory,andtheprocessofsprayinghighemissivitycoatingwasselectedaftercomaringtwosurfacetreatmentmethods.Thecombinationstructurewithtwosplitcircularconeswasdesignedtosolvetheproblemsofmachiningdifficultyandcoatingaccumulationinconventionalconetips.Theeffectiveemissivityofthedevelopedblackbodycavitywasevaluatedbytheoreticalcalculation,raytracingsimulationandexperimentalmeasurement.Theresultshowsthattheeffectiveemissivityofthedevelopedblackbodycavityreachesupto0.997,whichmeetstherequirementofhigh-precisioncalibrationtestofinfraredloads.Keywords:blackbodycavity;effectiveemissivity;structuraloptimaldesign;surfacetreatment收稿日期:2022-08-15;修回日期:2023-01-12基金项目:科技部重点研发计划项目(编号:2022YFB3903104)引用格式:徐骏,费志禾,王惠芬,等.高发射率水浴黑体腔优化设计与测试[J].航天器环境工程,2023,40(1):18-23XUJ,FEIZH,WANGHF,etal.Optimaldesignandtestingofhigh-emissivitywater-bathblackbodycavity[J].SpacecraftEnvi...